Air Loader Air Requirements: Pressure, Flow and Compressor Matching
To match an air loader to a compressor, confirm the selected model’s working pressure and air consumption, then check what the supply line can deliver at the machine while it works. Pressure alone is not enough to approve a compressor for underground loading.

Start with the air loader working pressure
HNYT publishes the following working-pressure ranges for its rail-mounted pneumatic rock loaders. Use the selected model’s data rather than applying one pressure range to every machine.
These figures describe working pressure, not air consumption or compressor motor size. They are model references, not instructions to set a compressor to the upper end of the range. Confirm the supplied configuration with HNYT.

Confirm air consumption before choosing a compressor
Pressure and flow answer different questions. The supply must maintain the required pressure while delivering enough air for the loading task. A compressor pressure reading by itself does not establish whether that demand can be met.
The linked product tables do not state whole-machine air consumption. Request the selected configuration’s air requirement before specifying compressor capacity. Ask whether a quoted flow covers one motor, one operating function or the complete machine, and under which operating conditions it applies.
Request the flow unit and measurement basis, including whether the figure is expressed as free-air delivery. Have the compressor supplier compare its delivered-air specification at the required pressure with the loader requirement on the same basis. Do not turn an individual motor figure into a whole-machine requirement without confirming which functions operate together.
Review the complete air supply route
HNYT’s air-supply guidance distinguishes pressure at the compressor from pressure at the loader during work. Long or narrow hoses, couplings, restrictions and leaks can reduce the air available at the machine. Other tools sharing the line also affect the supply.
For an existing installation, provide the pressure readings at both ends during representative loading. For a planned installation, send the route length, hose or pipe internal diameter, connection arrangement and the tools expected to operate at the same time. Have this layout reviewed before accepting the compressor match.

What to send for a comparable quotation
Give HNYT and the compressor supplier the same operating information so the proposal covers the loader, shared demand and supply route together:
- Loader model and proposed configuration.
- Compressor data sheet: delivered airflow and the pressure at which it is specified.
- Loader air requirement, its measurement basis and planned loading cycle.
- Pipe and hose lengths, internal diameters, connections and available pressure readings.
- Other pneumatic equipment expected to run at the same time.
Include tunnel dimensions, rail gauge and the receiving mine-car arrangement for the loader selection itself. These site details complement the air-supply review; they do not replace the missing flow specification.
FAQ
Does a matching pressure rating prove compatibility?
No. Confirm airflow as well as pressure at the working position, with the supply route and shared demand included in the review.
What if I cannot find an air-consumption figure?
Request a configuration-specific figure and its operating conditions from HNYT. The product-page pressure ranges alone do not provide a compressor capacity.
Will a larger compressor solve a restrictive hose run?
Not necessarily. HNYT’s guidance identifies hose restrictions and leaks as separate causes of inadequate supply. Review the route as well as compressor output.
Discuss your air supply requirements
Contact HNYT with your air loader model, compressor data sheet, supply-route details and shared air demand. Include working-pressure readings where available so the proposed loader and compressed-air supply can be reviewed together.